The reclaimed refrigerants we supply are recovered as raw material from across the Nordic region and reclaimed to virgin-grade quality in Helsinki in accordance with AHRI-700 and ISO 11650:1999 standards.
Our reclaimed refrigerants have a carbon footprint more than
40 times lower that of equivalent virgin refrigerants.Â
Read more about the LCA study we have conducted.
Nearly all refrigerants can be reclaimed. Refrigerant reclamation means processing recovered refrigerant to restore it to virgin-grade quality. A refrigerant can be classified as reclaimed once it has undergone a purification process using equipment compliant with AHRI-740 and ISO 11650 standards, followed by laboratory analysis confirming that the reclaimed refrigerant meets the AHRI-700 quality standard.
We are committed to the European Fluorocarbons Technical Committee (EFCTC) programme.
HFC- & HFO-refrigerants
Below you will find reclaimed HFC refrigerants including R404A, R407C, R410A, R134a, R422D and R32, as well as virgin HFO refrigerants such as R449A, R448A, R1234yf, R1234ze and R452A.
R32
Reclaimed
GWP
677
ODP
0
Safety class
A2L
UN-number
UN 3252
Composition
100% R32
(difluoromethane)
R134a
Reclaimed
GWP
1430
ODP
0
Safety class
A1
UN-number
UN 3159
Composition
100% R134a (1,1,1,2-tetrafluoroethane)
R404A
Reclaimed
GWP
3922
ODP
0
Safety class
A1
UN-number
UN 3337
Composition
R134a 4% (+-2); R125 44% (+-2); R143a 52% (+-1)
R407C
Reclaimed
GWP
1774
ODP
0
Safety class
A1
UN-number
UN 3340
Composition
R32 23%(+-2); R125 44%(+-2); R134a 52%(+-2)
R410A
Reclaimed
GWP
2088
ODP
0
Safety class
A1
UN-number
UN 3163
Composition
R32 50%(+0,5-1,5); R125 50%(+0,5-1,5)
R449A
Virgin
GWP
1397
ODP
0
Safety class
A1
UN-number
UN 1078
Composition
R32 24.3%; R125 24.7%; R134a 25.7%; R1234yf 25.3%
R448A
Virgin
GWP
1387
ODP
0
Safety class
A1
UN-number
UN 3163
Composition
R32 26%; R125 26%; R134a 21%; R1234yf 20%; R12234ze 7%
R1234yf
Virgin
GWP
4
ODP
0
Safety class
A2L
UN-number
UN 3161
Composition
100% R1234yf (2,3,3,3-tetrafluoropropene)
R1234ze
Virgin
GWP
7
ODP
0
Safety class
A2L
UN-number
UN 3161
Composition
100% R1234ze (trans-1,3,3,3-tetrafluoropropene)
R452A
Virgin
GWP
2140
ODP
0
Safety class
A1
UN-number
UN 1078
Composition
R32 11%; R125 59%;
R1234yf 30%
R513A
Virgin
GWP
573
ODP
0
Safety class
A1
UN-number
UN 3163
Composition
R134a 44%;
R1234yf 56%
R454B
Virgin
GWP
466
ODP
0
Safety class
A2L
UN-number
UN 3161
Composition
R32 68.9%;
R1234yf 31.1%
R455A
Virgin
GWP
146
ODP
0
Safety class
A2L
UN-number
UN 3161
Composition
R32 21.5%; R1234yf 75.5%; R744 (CO2) 3%
The use of virgin refrigerants with high GWP has been significantly restricted since 2020. An exception applies to reclaimed refrigerants, which can be used until the end of 2031.
Natural resources are limited, and their continuous extraction creates significant emissions and environmental impacts. Although reclaimed refrigerants have the same GWP as their virgin equivalents, the carbon footprint generated during their production (per kilogram) is significantly lower compared to manufacturing new refrigerants.
How can we help?
Eco Scandic is the first company in the Nordic region focused on refrigerant reclamation, restoring refrigerants to virgin-grade quality through advanced recycling.
Our mission is to provide sustainable circular economy solutions that help customers maximize the value of their resources by extending the lifecycle of refrigeration systems while reducing emissions.
Contact us
Fill in the form and we will contact you shortly.
Talk to an expert